Product Range

Equipment for every part of a power project — generation, storage, conversion, distribution and grid connection. All product families are supplied from established manufacturers and specified to the relevant IEC standards. Datasheets and type test reports are provided with each offer.

Transmission & Substation

High voltage components for transmission substations and grid connection points, from distribution level up to 500 kV.

Instrument transformers

Current transformers

Inductive voltage transformers

Capacitive voltage transformers

Combined current and voltage transformers

Auxiliary service voltage transformers

Power line carrier

Coupling capacitors

Line traps

Surge protection

Station-class surge arresters, porcelain housing

Station-class surge arresters, silicone housing

Surge counters and arrester monitoring devices

Insulation and conductors

Porcelain station post insulators

Aluminium and copper tubular busbar

HV connectors, clamps and earthing clamps

Protection and testing

Trip, lockout and supervision relays

Test blocks and test plugs

Instrument transformers and surge arresters are selected against your system voltage, short-circuit level and protection scheme. Send the relevant sections of the substation specification and we will propose matching ratings.

Solar PV Modules

Monocrystalline modules for utility-scale, commercial and residential projects, selected by technology, format and power class to match your design.

Cell technology

N-type TOPCon

Heterojunction (HJT)

Mono PERC half-cut

Formats

Monofacial and bifacial

Glass-backsheet and glass-glass

Full-black modules for rooftop and architectural use

Power classes

410–480 W — rooftop and commercial

535–575 W — commercial and utility-scale

610–705 W — large-format modules for utility-scale plants

Datasheets, IEC test certificates and warranty terms are supplied with each offer. Pallet and container loading is confirmed per order.

Energy Storage & Power Conversion

Battery storage and power conversion equipment for utility, commercial and off-grid applications — as complete systems or as modules for system integrators.

Complete systems

Containerised battery energy storage systems (BESS)

Power conversion systems (PCS)

Hybrid inverter cabinets for solar, storage and grid

Residential all-in-one storage systems

Modules for system integrators

Bidirectional AC/DC converters

Bidirectional DC/DC converters and DC/DC cabinets

Static transfer switches

Energy management systems (EMS)

Batteries and inverters

LiFePO4 lithium batteries

Lead-acid batteries

On-grid, off-grid and hybrid solar inverters

Storage systems are sized against your load profile, required backup time or grid service. Share the application and target capacity, and we will propose a configuration.

Medium Voltage Equipment

Switchgear and distribution equipment for industrial plants, substations and utility networks.

Air-insulated switchgear (AIS)

12 / 17.5 / 24 kV

36 / 40.5 kV

Gas-insulated switchgear (GIS)

12 / 17.5 / 24 kV

36 / 40.5 kV

Other MV equipment

Ring main units

MV circuit breakers — vacuum and SF6

Compact substations (kiosk type)

MV soft starters

Direct-on-line motor starters

Autotransformer panels for MV motors

Rated voltages up to 40.5 kV. Air-insulated and gas-insulated configurations, indoor and outdoor. Protection degrees to IP 21 / IP 23 / IK 05, other degrees on request. Metal-clad and metal-enclosed constructions available depending on the application.

Low Voltage Systems

Distribution, control and specialised panels for industrial and commercial installations.

Main distribution panels up to 7400 A

Motor control centres (MCC)

Surface and flush mounted sub-distribution boards

Compensation panels

Automation and PLC panels

Marine application panels

Fuel and gas station panels

Transformer fan panels

Explosion-proof LV panels

Telecom panels — RTU, PABX, AC-DC, MDF

Fixed type LV cubicles

Withdrawable type LV cubicles

LV circuit breakers — ACB, MCCB, MCB

Reactive Power Compensation & Power Quality

An area of long-standing technical depth within Argen Group. Poor power factor and harmonic distortion cost plants money in reactive energy billing, transformer capacity and equipment life. We size and supply the correction.

Low voltage range

Fixed capacitor banks with integrated circuit breaker protection, 10–175 kVAr, 400 V networks

Automatic capacitor banks with electromechanical contactor switching, controlled by an integrated power factor controller

Automatic capacitor banks with solid-state (thyristor) switching, for installations with fast load cycles or voltage-sensitive equipment — response time under 50 milliseconds, no contact wear, suitable for welding plants, robotics and drive systems

Detuned reactor versions for networks with harmonic pollution above 15%

Thyristor switches for existing banks being upgraded to fast switching

Active compensation

Active harmonic filters — real-time harmonic current injection for networks where passive filtering is insufficient or load conditions vary

Reactive power conditioners (RPC) — combined reactive compensation, harmonic filtering and load balancing in a single unit

Suitable for installations with non-linear loads: drives, rectifiers, arc furnaces, welding plants and data centres

Medium voltage range

Fixed capacitor banks, delta configuration, up to 12 kV and 2500 kVAr

Fixed capacitor banks, double star configuration, up to 24 kV and 5000 kVAr

Large double star banks up to 36 kV and 20,000 kVAr

Automatic banks with power factor control

Open rack (IP 00) and cubicle-mounted (IP 21 / IP 23) assemblies, indoor and outdoor

Dynamic compensation (MV)

Static VAr compensators (SVC) — thyristor-controlled reactive power for rapidly varying loads such as arc furnaces, rolling mills and traction supply

STATCOM — voltage source converter based compensation for flicker reduction, voltage support and fast reactive response

Thyristor-switched shunt reactor banks

Protection and accessories

Detuned reactors, tuned to 135 / 190 / 215 Hz for 50 Hz networks

Damping reactors and quick discharge reactors

HRC fuse protection and unbalance / differential protection

Passive harmonic filters, tuned to the specific harmonic order to be eliminated

Vacuum contactors, earthing switches, motorised switches

Power factor controllers

For installations with significant harmonic distortion, we provide supply network analysis with harmonic voltage and current measurement, simulation of filter compatibility, and filter component calculation.

Drives & Motor Control

Low voltage variable speed drives

Medium voltage variable speed drives

Soft starters, LV and MV

Motor protection and control equipment

Monitoring, Control & Energy Management

Remote terminal units (RTU)

Energy analysers — portable and panel mounted

Reactive power controllers

SCADA-based energy management systems for multi-site and multi-feeder installations

Where a plant needs visibility rather than more hardware, metering and energy management is often the cheaper intervention. We supply the instrumentation and the system layer together.

Not sure which configuration fits?

Send us your single line diagram or project summary and we will propose a matched equipment package.

Request a Quote